Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 388
Filter
1.
Article in English | LILACS-Express | LILACS | ID: biblio-1430564

ABSTRACT

In 1995 Gebeck & Merrifield studied a successful and unsuccessful treated Class I and Class II's samples; they found a -1.33 mm intrusion in the former and a 0.80 mm extrusion in the latter. The purpose of this article was to perform a cephalometric evaluation of maxillary incisors torque and vertical changes. We studied a sample of 129 patients, 30 males and 99 females, taken from The Charles H. Tweed Foundation Long Term Study, at pretreatment mean age 12.93 years, posttreatment mean age 16.19 years and follow up post retention mean age 29.83 years, a 13.88 years interval. The records were collected from private practitioners across the North American continent who used Standard Edgewise Mechanics and were members of the Charles H. Tweed Foundation. All patients were Class I and II American whites treated with the extraction of 4 premolars. We found an Upper anterior incisal edge to PP vertical linear measurement 28.7 and 29.2 mm, +0.53 mm (p<0.019) from pretreatment to posttreatment. The average Upper 1 to SN angle was 103.2 ° at pretreatment and 100.1° at posttreatment, -3.2° (p<0.000), Upper 1 to PP 111.0° and 108.9°, -2.2° (p<0.000), the three of them statistically significant. Conversely, Upper 1 to commissure was not. The four measurements were also statistically significant posttreatment to follow up, upper anteriors kept losing torque after posttreatment, and less upper anteriors surface was below the commissure. Some torque loss and vertical extrusion can be expected while treating patients with extractions of four premolars, therefore, upper incisor inclination increase and vertical change by itself cannot determine the success of treatment.


En 1995, Gebeck y Merrifield estudiaron muestras de Clase I y Clase II tratadas con éxito y sin éxito; encontraron una intrusión de -1,33 mm en el primero y una extrusión de 0,80 mm en el segundo. El propósito de este artículo fue realizar una evaluación cefalométrica del torque y los cambios verticales de los incisivos maxilares. Estudiamos una muestra de 129 pacientes, 30 hombres y 99 mujeres, tomados del estudio a largo plazo de la Fundación Charles H. Tweed, con una edad media previa al tratamiento de 12,93 años, una edad media posterior al tratamiento de 16,19 años y una edad media de seguimiento posterior a la retención de 29,83 años, con un intervalo de de 13,88 años. Los registros se recopilaron de médicos privados en todo el continente norteamericano que utilizaron Standard Edgewise Mechanics y eran miembros de la Fundación Charles H. Tweed. Todos los pacientes eran blancos americanos Clase I y II tratados con extracción de 4 premolares. Encontramos una medida lineal vertical del borde incisal anterior superior a PP de 28,7 y 29,2 mm, +0,53 mm (p<0,019) desde el pretratamiento hasta el postratamiento. El promedio del ángulo Superior 1 a SN fue de 103,2° en el pretratamiento y 100,1° en el postratamiento, -3,2° (p<0,000), Superior 1 a PP 111,0° y 108,9°, -2,2° (p<0,000), los tres estadísticamente significante. Por el contrario, Superior 1 a la comisura no lo era. Las cuatro mediciones también fueron estadísticamente significativas para el seguimiento después del tratamiento, los dientes anteriores superiores siguieron perdiendo torsión después del tratamiento y se observó menor superficie de los dientes anteriores superiores debajo de la comisura. Se puede esperar cierta pérdida de torque y extrusión vertical al tratar a pacientes con extracciones de cuatro premolares, por lo tanto, el aumento de la inclinación del incisivo superior y el cambio vertical por sí mismos no pueden determinar el éxito del tratamiento.

2.
Braz. dent. sci ; 26(4): 1-9, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1523759

ABSTRACT

Introduction: The development of new biomaterials with improved properties is a trend in regenerative medicine. The successful healing of implants is related to their osseointegration and the topographic geometry of their surface. Treatment with argon plasma acts on the surface of the implants, bringing several benefits to their osseointegration in the body. Material and Methods: Previously the in vivo study, the topography implants were observed by scanning electron microscopy (SEM). Following the implants were inserted in 14 male rats, and one perforation was made in the right and left tibias for implant placement without the surface treatment (control group), and with the argon plasma surface treatment (experimental group), respectively. The rats were euthanized at 4 weeks, a time in which tibia fragments were submitted for histological and histomorphometric examination, and torque removal test for comparison and analysis of osseointegration. Results: The SEM images showed the argon plasma surface treatment altered the topography. At the end of the study, both greater bone formation and better osseointegration were verified in the experimental group, and a statistically significant difference between the groups was observed. Conclusion: It was concluded that implants with this surface treatment can bring more practicality in the rehabilitation treatment, and more comfort in the patients' postoperative time (AU)


Introdução: O desenvolvimento de novos biomateriais com propriedades aprimoradas é uma tendência na medicina regenerativa. A cicatrização bem-sucedida dos implantes está relacionada à sua osseointegração e à geometria topográfica de sua superfície. O tratamento com plasma de argônio atua na superfície dos implantes, trazendo diversos benefícios para sua osseointegração no corpo. Materiais e Métodos: Antes do estudo in vivo, a topografia dos implantes foi observada por microscopia eletrônica de varredura (MEV). Em seguida, os implantes foram inseridos em 14 ratos machos, e uma perfuração foi feita nas tíbias direita e esquerda para a colocação do implante sem o tratamento de superfície (grupo controle) e com o tratamento de superfície de plasma de argônio (grupo experimental), respectivamente. Os ratos foram sacrificados após 4 semanas, momento em que fragmentos das tíbias foram submetidos a exame histológico e histomorfométrico, além do teste de remoção de torque para comparação e análise da osseointegração. Resultados: As imagens de MEV mostraram que o tratamento de superfície com plasma de argônio alterou a topografia. Ao final do estudo, foi verificada maior formação óssea e melhor osseointegração no grupo experimental, e foi observada diferença estatisticamente significativa entre os grupos. Conclusão: Concluiu-se que os implantes com esse tratamento de superfície podem trazer mais praticidade no tratamento de reabilitação e maior conforto no pós-operatório dos pacientes (AU)


Subject(s)
Animals , Rats , Titanium , Dental Implants , Osseointegration , Torque
3.
Biosci. j. (Online) ; 39: e39036, 2023. tab, graf
Article in English | LILACS | ID: biblio-1428171

ABSTRACT

This article aims to associate patient-reported pain intensity in the immediate seven days after dental implant surgery with surgical factors, sex and patient age. The sample was composed of 108 patients from a dental school in southern Brazilian, between 2018 and 2020. The variables torque, pre- and postoperative medication, healing of first and second intention, gender, age, number of quadrants, number of implants and type of surgery were related to the outcome pain. Pain was reported every day by the patient until the seventh day after surgery, using a visual analogic scale (VAS). Univariate Poisson regression models were used to assess the relationship among pain and the factors. Rate ratios were obtained with 95% of confidence intervals. Overall pain was reported as moderate/intense (VAS: 3-10) by 30.56% of patients, mild pain (VAS: 1-3) by 55.56%, and no pain symptoms were reported by 13.89% of patients. Individuals which the implants were installed with high torques (50-80 N) showed more pain (p=0.03) compared to patients which the implants were installed with regular torque (30-45 N). The other factors evaluated were not significant. The torque was the most relevant factor related to pain among the evaluated by the study. High torque generates more postoperative pain than lower torque. The factors gender, age, number of operated quadrants, number of installed implants, type of surgery and pre and postoperative analgesic did not interfere in the patient's pain during the first week after surgery.


Subject(s)
Pain, Postoperative , Dental Implants , Torque
4.
Braz. j. med. biol. res ; 56: e12202, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1420767

ABSTRACT

Upper and lower limbs can be affected by several diseases and changes related to current life habits, such as the sedentarism, technological advances, and even eating habits. This cross-sectional study investigated morphological adaptations of the biceps brachii muscle and the performance of the elbow flexors in healthy individuals in the early phase of aging. Thirty-two volunteers were separated according to age range (3rd, 4th, and 5th decades of life) and sex. Smaller diameters and subtypes of fibers were evaluated using muscle biopsies, and peak torque and total work were assessed using an isokinetic dynamometer. The variables were compared considering sex and decade, using mixed-effects linear models. The smaller diameter of all fiber types did not differ significantly between age groups for either sex. The proportion of oxidative fibers was reduced in male participants in the 4th (-20%) and 5th (-6%) decades of life compared to the 3rd decade, and there was an increase in the number of oxidative fibers in women from the 4th (+14%) to the 5th decade of life. There were no significant changes in the peak torque and total work between the analyzed age groups. The early phase of aging starts with alterations in the proportion of fibers, with a decrease in oxidative fibers in men and an increase in oxidative fibers in women. Smaller diameter, torque, and total work did not change over these decades of life.

5.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 667-672, 2023.
Article in Chinese | WPRIM | ID: wpr-974745

ABSTRACT

@#In many cases, tooth movement over a considerable distance is needed to meet the major goal of orthodontic treatment, which has always been to correct malocclusion and improve the facial profile in patients with skeletal malocclusion. However, tooth movement over a considerable distance also carries risks of dehiscence, fenestration, root exposure, and so forth. The reason lies in neglecting many limits for tooth movement, especially anatomical characteristics. This review focuses on structural limits for orthodontic molar movement, such as the alveolar cortex, the maxillary sinus floor, and the mandibular canal. In addition, we set the strategy in clinical orthodontics. For the alveolar cortex and the mandibular canal, orthodontists are recommended to move the root away from the cortical bone initially and formulate personalized molar movement plans according to clinical examination and cone-beam computed tomography (CBCT) and other imaging examinations. First, the molar root was controlled by torque away from the bone plate, and then, the molar movement amount and direction were controlled according to the personalized movement path. In regard to the maxillary sinus floor, light and continuous forces and scientific biomechanics are suitable for bodily tooth movement. In summary, better therapeutic efficacy and long-term stabilization could be achieved by circumventing the limits and risks caused by anatomical limitations and characteristics.

6.
Journal of Medical Biomechanics ; (6): E587-E593, 2023.
Article in Chinese | WPRIM | ID: wpr-987990

ABSTRACT

国家自然科学基金项目(11932012、81400536),上海申康医院发展中心临床创新三年行动计划(SHDC2020CR3009A),上海交通大学医工(理)交叉基金(JYJC202130)

7.
Fisioter. Mov. (Online) ; 36: e36104, 2023. tab, graf
Article in English | LILACS | ID: biblio-1421462

ABSTRACT

Abstract Introduction Kinesio tape (KT), although frequently used in sports, is still a matter of debate, and the results of studies that evaluated its effects on muscle strength (MS) in athletes are still inconclusive and contradictory. Objective To evaluate the effect of a progressive KT tension protocol on knee MS in runners over an eight-week intervention. Methods Clinical trial involving 49 runners of both sexes randomized into two groups: KT (KT with progressive tension protocol) and placebo (KT without tension). The MS of knee flexors and extensors was evaluated by isokinetic dynamometer (60º/s and 90º/s) at four moments: (1) without KT; (2) with KT and without tension; (3) without KT (after 8 weeks after of intervention); (4) with KT and with tension (after 8 weeks after of intervention). Inter- and intra-group comparisons were made. The significance level adopted was 95% (p < 0.05). Results There were no significant differences in MS between the groups at any of the evaluated moments. There was a statistically significant difference in MS (60º/s) in both groups (KT and placebo) when comparing moments 4 and 2 for knee flexors, and in the placebo group between moments 4 and 2 and moments 4 and 3 for knee extensors. Conclusion The progressive tension protocol of KT was not able to intervene in the SM gain of knee flexors and extensors of runners in inter and intragroup comparisons.


Resumo Introdução A Kinesio tape (KT), apesar de muito utilizada na prática esportiva, ainda é motivo de debate e os resultados de estudos que avaliaram seus efeitos na força muscular (FM) em atletas ainda são inconclusivos e contraditórios. Objetivo Avaliar o efeito de um protocolo de tensão progressiva KT na FM do joelho em corredores ao longo de uma intervenção de oito semanas. Métodos Ensaio clínico envolvendo 49 corredores de ambos os sexos randomizados em dois grupos: KT (KT com protocolo de tensão progressiva) e placebo (KT sem tensão). A FM dos flexores e extensores do joelho foi avaliada por dinamômetro isocinético (60º/s e 90º/s) em quatro momentos: (1) sem KT; (2) com KT e sem tensão; (3) sem KT (após 8 semanas); (4) com KT e com tensão (pós-protocolo 8 semanas). Comparações inter e intragrupos foram feitas. O nível de significância adotado foi de 95% (p < 0,05). Resultados Não houve diferenças signi-ficativas na FM entre os grupos em nenhum dos momentos avaliados. Houve diferença estatisticamente significante na FM (60º/s) em ambos os grupos (KT e placebo, quando comparados os momentos 4 e 2 para flexores de joelho, e no grupo placebo entre os momentos 4 e 2 e os momentos 4 e 3 para extensores de joelho. Conclusão O protocolo de tensão progressiva de KT não foi capaz de intervir no ganho de FM de flexores e extensores de joelho de corredores em comparações inter e intragrupos.


Subject(s)
Humans , Torque , Muscle Strength , Athletes , Knee
8.
Dental press j. orthod. (Impr.) ; 28(2): e2321345, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439988

ABSTRACT

ABSTRACT Objectives: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. Trial Design: Randomized clinical trial with a split-mouth study design. Setting: Department of Orthodontics, SRM Dental College, Chennai. Participants: Patients who required orthodontic mini-implants for anterior retraction in both arches. Methods: Self-drilling, tapered, titanium orthodontic mini-implants with and without surface treatment were placed in each patient following a split-mouth design. The maximum insertion and removal torques were measured for each implant using a digital torque driver. The failure rates were calculated for each type of mini-implant. Results: The mean maximum insertion torque was 17.9 ± 5.6 Ncm for surface-treated mini-implants and 16.4 ± 9.0 Ncm for non-surface-treated mini-implants. The mean maximum removal torque was 8.1 ± 2.9 Ncm for surface-treated mini-implants and 3.3 ± 1.9 Ncm for non-surface-treated mini-implants. Among the failed implants, 71.4% were non-surface-treated mini-implants and 28.6% were surface-treated mini-implants. Conclusion: The insertion torque and failure rate did not differ significantly between the groups, whereas the removal torque was significantly higher in the surface-treated group. Thus, surface treatment using sandblasting and acid etching may improve the secondary stability of self-drilling orthodontic mini-implants. Trial registration: The trial was registered in the Clinical Trials Registry, India (ICMR NIMS). Registration number: CTRI/2019/10/021718


RESUMO Objetivos: Este ensaio clínico foi conduzido para avaliar a estabilidade e a taxa de falha de mini-implantes ortodônticos com superfície tratada, e determinar se elas diferem das dos mini-implantes ortodônticos sem superfície tratada. Desenho do estudo: Ensaio clínico randomizado com desenho de boca dividida. Instituição: Department of Orthodontics, SRM Dental College, Chennai/India. Participantes: Pacientes que necessitavam de mini-implantes ortodônticos para retração anterior em ambas as arcadas. Métodos: Mini-implantes ortodônticos autoperfurantes, cônicos, de titânio com ou sem tratamento de superfície, foram colocados em cada paciente, seguindo um desenho de boca dividida. Os torques máximos de inserção e de remoção foram medidos para cada mini-implante, usando um torquímetro digital. As taxas de falha foram calculadas para cada tipo de mini-implante. Resultados: O valor médio do torque máximo de inserção foi de 17,9 ± 5,6 Ncm para mini-implantes com superfície tratada e 16,4 ± 9,0 Ncm para mini-implantes sem superfície tratada. O valor médio do torque máximo de remoção foi de 8,1 ± 2,9 Ncm para mini-implantes com superfície tratada e 3,3 ± 1,9 Ncm para mini-implantes sem superfície tratada. Entre os implantes que falharam, 71,4% eram mini-implantes sem superfície tratada e 28,6% eram mini-implantes com superfície tratada. Conclusão: O torque de inserção e a taxa de falha não diferiram significativamente entre os grupos; porém, o torque de remoção foi significativamente maior no grupo com superfície tratada. Assim, o tratamento de superfície com jateamento e condicionamento ácido pode melhorar a estabilidade secundária dos mini-implantes ortodônticos autoperfurantes. Registro do estudo: Esse estudo foi registrado no Clinical Trials Registry, Índia (ICMR NIMS). Número de registro: CTRI/2019/10/021718

9.
Fisioter. Pesqui. (Online) ; 30: e22006823en, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1506236

ABSTRACT

ABSTRACT Muscle strength is an essential part of the functional assessment of health professionals to select and analyze the effects of clinical interventions. This study aimed to determine the influence of gender and age on isometric strength of hip and knee muscle groups. A total of 127 subjects (50.4% men), aged from 20 to 49 years (stratified into three groups: 20-29 years; 30-39 years; and 40-49 years) participated in this study. A hand-held dynamometer was used to measure isometric normalized torque of the hip abductors, hip external rotators, knee extensors, and knee flexors muscles. Regressions and a two-way analysis of variance were used to identify the influence of age and gender on torque of each muscle group. Age and gender were included in the regression model for all groups. Generally, men aged 20-29 and 30-39 were stronger than age-paired women. For participants aged 40-49, torque was similar for men and women for all muscle groups. There was no difference among age groups for women. Generally, young men were stronger than older men. The association between age and gender in hip and knee strength was proved and liable of subgroup stratification after measurements with a hand-held isometric dynamometer.


RESUMEN La fuerza muscular es un componente básico de la evaluación funcional de los profesionales de la salud para seleccionar y analizar los efectos de las intervenciones clínicas. El objetivo de este estudio fue determinar la influencia del sexo y de la edad en las mediciones de fuerza isométrica de los grupos musculares de la cadera y la rodilla. En el estudio participaron 127 sujetos (50,4% hombres), de entre 20 y 49 años de edad (estratificados en grupos: 20 a 29 años; 30 a 39 años; y 40 a 49 años). El torque isométrico normalizado de los abductores y rotadores externos de la cadera y de los extensores y flexores de la rodilla se midió con un dinamómetro manual. Se utilizaron regresiones y el análisis de varianza (Anova) para identificar la influencia de la edad y el sexo en el torque. Tanto la edad como el sexo se incluyeron en el modelo para todos los grupos musculares. En general, los hombres de entre 20 y 29 años y los de 30 a 39 mostraron tener más fuerza que las mujeres del mismo grupo de edad. Para los participantes de 40 a 49 años, el torque fue similar entre hombres y mujeres para todos los grupos musculares. No hubo diferencias entre los grupos de edad en el grupo de mujeres. En general, los hombres más jóvenes demostraron ser más fuertes que los hombres de mediana edad. La relación entre la edad y el sexo en la fuerza muscular de la cadera y la rodilla se probó y demostró ser susceptible a la estratificación después de las mediciones realizadas con el dinamómetro manual.


RESUMO A força muscular é um componente essencial da avaliação funcional de profissionais da saúde para selecionar e analisar efeitos de intervenções clínicas. O objetivo do estudo foi determinar a influência do sexo e da idade sobre medidas de força isométrica de grupos musculares do quadril e do joelho. Participaram da pesquisa 127 sujeitos (50,4% homens), com idade de 20 a 49 anos (estratificados em grupos: 20 a 29 anos; 30 a 39 anos; e 40 a 49 anos). O torque isométrico normalizado de abdutores e rotadores externos de quadril e extensores e flexores de joelho foi medido com dinamômetro manual. Regressões e uma análise de variância (Anova) foram usados para identificar a influência da idade e do sexo sobre o torque. Tanto idade quanto sexo foram incluídos no modelo para todos os grupos musculares. Em geral, homens de 20 a 29 anos e de 30 a 39 anos demonstraram mais força do que mulheres da mesma faixa etária. Para participantes de 40 a 49 anos, o torque foi similar entre homens e mulheres para todos os grupos musculares. Não houve diferença entre as faixas etárias no grupo de mulheres. Em geral, homens mais jovens se mostraram mais fortes do que homens mais velhos. A relação entre idade e sexo na força muscular do quadril e do joelho foi provada e se mostrou passível de estratificação após as medições feitas com o dinamômetro manual.

10.
Arq. ciências saúde UNIPAR ; 26(3): 901-909, set-dez. 2022.
Article in Portuguese | LILACS | ID: biblio-1399503

ABSTRACT

Com o aumento da população brasileira e consequentemente o número de edêntulos realizando tratamentos reabilitadores com implantes dentários, se tornou frequente aparições de complicações como, por exemplo, sua fratura. O presente trabalho tem por objetivo apresentar as causas prováveis relacionadas a fratura de implante dentário, através de um relato de caso clínico onde pode-se avaliar a condição da fratura apresentada e como foi solucionada. Após a analise do caso clínico, foi constatado que o principal fator que levou a sua fratura foram as sobrecargas oclusais associadas ao mal posicionamento e a qualidade do implante antigo. A partir disso, conclui-se que é de extrema importância o cirurgião dentista estar ciente de todas as possíveis complicações acerca do implante dentário, afim de realizar um bom planejamento cirúrgico diminuindo a taxa de insucesso levando a um bom prognóstico.


With the increase of the Brazilian population and, consequently, the number of edentulous individuals undergoing rehabilitation treatmentes with dental implants, the appearance of complications such as, for example, their fracture has become frequent. The present work aims to presente the probable causes related to dental implant fracture, trough a clinical case report where the condition of the fracture presented and how it was resolved can be evaluated. After analyzing the clinical case, it was found that de main factor that led to its fracture were the occlusal overloads associated with poor positioning and the quality of the old implant. From this , it is concluded that it is extremely important for the dental surgeon to be aware of all possible complications regarding the dental implant, in order to carry out a good surgical planning, reducing the failure rate, leading to a good prognosis.


Con el aumento de la población brasileña y, en consecuencia, del número de personas edéntulas que se someten a tratamientos de rehabilitación con implantes dentales, las complicaciones, como las fracturas, se han vuelto comunes. El presente trabajo tiene como objetivo presentar las probables causas relacionadas con la fractura de implantes dentales, a través del reporte de un caso clínico, donde se puede evaluar la condición de la fractura presentada y la forma en que fue resuelta. Tras analizar el caso clínico, se comprobó que el principal factor que condujo a la fractura fue la sobrecarga oclusal asociada a una mala colocación y a la calidad del implante antiguo. Esto lleva a la conclusión de que es muy importante que el cirujano dental conozca todas las posibles complicaciones de los implantes dentales, para realizar una buena planificación quirúrgica, reduciendo así la tasa de fracasos y consiguiendo un buen pronóstico.


Subject(s)
Humans , Male , Middle Aged , Prostheses and Implants , Dental Implants , Causality , Bruxism/complications , Clinical Diagnosis/education , Osseointegration , Torque , Dental Implantation, Endosseous/instrumentation , Dentists/education , Fractures, Bone
11.
Indian J Public Health ; 2023 Jun; 67(2): 316-319
Article | IMSEAR | ID: sea-223933

ABSTRACT

The study aims to define the sex‑based reference data for muscle mass and strength among healthy young Indians and to compare the data from the present study with available literature. Healthy Indian adults (n = 100) aged between 18 and 40 years were recruited. The assessment of muscle mass and strength was performed. The body cell mass (BCM), fat‑free mass, and muscle strength parameters were significantly higher among males compared to females (P < 0.001). A comparison of the current study data with the available literature showed that though BCM was comparable, Indians demonstrated a significantly lower isometric peak torque (P < 0.001 for both sexes). These findings suggest that Indians tend to have a lower muscle strength compared to the Western population, despite having a comparable BCM content.

12.
Odovtos (En línea) ; 24(1)abr. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1386569

ABSTRACT

Abstract Immediate loading of full-arch prostheses on dental implants in the upper arch is challenging, as the bone is of low quality and obtaining sufficient torque may be difficult. The purpose of this case report is to describe the rehabilitation of a full- arch by means of placement of four internal tapered connection tilted implants and immediate loading. A 65-year-old man sought dental care with a partially edentulous upper arch. The teeth presented mobility and were extracted. In a second step, two conventional-length implants were placed in the anterior region and two tilted and nasal wall-directed extra-long implants in the posterior region. The insertion torques of 60 N.cm allowed the installation of an immediate prosthesis (hybrid). The clinical case report suggests that the placement of tilted and extra-long implants in the paranasal bone and immediate loading may be a viable option for rehabilitation of the edentulous upper arch.


Resumen La carga inmediata de prótesis de arco completo en implantes dentales en el arco superior es un desafío, ya que el hueso es de baja calidad y puede ser difícil obtener un par suficiente. El propósito de este reporte de un caso es describir la rehabilitación de un arco completo mediante la colocación de cuatro implantes inclinados de conexión cónica interna y carga inmediata. Un hombre de 65 años buscó atención dental con un arco superior parcial sin dientes. Los dientes presentaron movilidad y fueron extraídos. En un segundo paso, se colocaron dos implantes de longitud convencional en la región anterior y dos implantes extralargos inclinados y dirigidos a la pared nasal en la región posterior. Los pares de inserción de 60 N.cm permitieron la instalación de una prótesis inmediata (híbrida). El informe del caso clínico sugiere que la colocación de implantes inclinados y extralargos en el hueso paranasal y la carga inmediata pueden ser una opción viable para la rehabilitación del arco superior desdentado.


Subject(s)
Humans , Male , Aged , Dental Implants , Suture Anchors
13.
Ciênc. rural (Online) ; 52(1): e20200966, 2022. graf
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1286045

ABSTRACT

ABSTRACT: Over the past few years, changes have been observed in the behavior of typical performance curves, after higher technology has been incorporated into the agricultural tractor engines, either to satisfy the ceiling of the new pollutant gas emission limits or to achieve better efficiency. The aim of this study was to assess the typical performance behavior of an agricultural tractor engine, possessing electronic injection management, turbocharger, aftercooler and EGR (Exhaust Gas Recirculation) treatment system. An analysis was done of the information the manufacturers provided, in terms of nominal power, maximum power and maximum power with Booster, maximum torque and maximum torque with Booster. From the results, the percentage difference between the nominal power and maximum power were found to hover anywhere from 1.49 to 11.97%, for the same manufacturer, 0% in another manufacturer and 9% in a third manufacturer, for all the models. Similar results were noted for the data reported on the maximum torque and maximum torque with Booster, giving 0.62% as the minimum value, 7.44% as the average value and 12.65% as the maximum value for the entire series.


RESUMO: O comportamento das curvas típicas de desempenho passou por alterações nos últimos anos, com a adoção de maior tecnologia pelos motores de tratores agrícolas, seja para atender aos novos limites de emissões de gases poluentes ou na busca por maior eficiência. Este trabalho teve como objetivo avaliar o comportamento típico de desempenho de um motor de trator agrícola, equipado com gerenciamento eletrônico da injeção, turbocompressor, aftercooler e sistema de tratamento de gases EGR (Exhaust Gas Recirculation). Também foram analisadas as informações disponibilizadas pelos fabricantes para os dados de potência nominal, potência máxima e potência máxima com Booster, torque máximo e torque máximo com Booster. Os resultados demonstraram que a diferença percentual entre a potência nominal e a potência máxima pode variar de 1,49% a 11,97% para um mesmo fabricante, 0% em outro e em um terceiro fabricante os valores situam-se em aproximadamente 9% para todos os seus modelos. Resultados similares foram encontrados para os dados informados de torque máximo e torque máximo com Booster, com valor mínimo encontrado de 0,62%, valor médio de 7,44% e o valor máximo de 12,65% para toda a série.

14.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 379-383, 2022.
Article in Chinese | WPRIM | ID: wpr-923546

ABSTRACT

@#Objective To analyze the characteristics of the muscle strength around the knee joint of chondromalacia patellae patients, and to explore the difference with normal people.Methods In March, 2021, 70 knee-onset chondromalacia patellae patients (experimental group) and 35 normal people (control group) were measured isokinetic muscle strength of flexion and extension of knee in angular velocities of 60°/s and 180°/s.Results At 60°/s and 180°/s, the peak torque, the peak torque-to-weight ratio and the total work of the flexor and extensor muscles on the affected side in the experimental group were lower than that of the control group (U > 1097.0, P<0.001). The peak torque, the peak torque-to-weight ratio and the total work of the flexor and extensor muscles at 60°/s and extensor muscles at 180°/s were lower on the affected side than on the healthy side in the experimental group (|Z| > 2.121, P<0.05). The peak torque ratios at 60°/s and 180°/s were more in the affected knees than in the healthy knees of experimental group and in the control group (U > 1810.0, |Z| >3.691, P<0.01).Conclusion The explosive force and endurance of the knee flexor and extensor has weakened in patients with chondromalacia patellae, and there is imbalance in knee joint muscle strength.

15.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 827-831, 2022.
Article in Chinese | WPRIM | ID: wpr-936415

ABSTRACT

@#Deep bite is a common clinical malocclusion that has a great impact on patients’ facial aesthetics and oral function. Bite opening is the key step in the treatment of deep bite, playing a decisive role in the development of mandible and the progress of orthodontic treatment. Torque and tip control during the correction of deep bites is a hot topic in orthodontics. The three-dimensional finite element method can accurately simulate clinical processes and conduct dynamic stress analysis, which provides the basis of the biomechanical mechanism. This paper reviewed the finite element analysis of various orthodontic systems for bite opening to provide a reference for clinical application. The emergence of mini-implants provided a new idea for anchorage control in bite opening. Finite element studies found that high-positioned mini-implants are beneficial for bodily tooth intrusion and proposed the ideal position for force application. For the finite element simulation of the reverse curve archwire, it was found that the intrusion and inclination of the anterior teeth increased with the curve depth of the archwire. The application of clear aligners has also been flourishing, but these forces are still difficult to effectively control. Finite element studies on their attachment design and corresponding tooth movement may be helpful to open the bite quickly and effectively. However, the existing studies still have modeling limitations. The structural simplification, linearization and nonstandard parameter definition of the model reduce model accuracy. Additionally, the existing research mostly focused on initial tooth movement, and studies on long-term tooth movement after bone remodeling are lacking. These studies are needed in the future.

16.
Pesqui. bras. odontopediatria clín. integr ; 22: e210120, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1422283

ABSTRACT

Abstract Objective: To examine the cyclic fatigue resistance and surface topography of TruNatomy and ProTaper Gold nickel-titanium rotary files and evaluate the presence of alterations to surface topography following instrumentation in simulated curved canals. Material and Methods: Twenty-four nickel-titanium instruments, twelve each of TN and PTG file systems, were evaluated for cyclic fatigue resistance. The rotary files were rotated in a simulated root canal with standardized diameter, angle of curvature, and radius of curvature in a custom-made cyclic fatigue testing device until the instrument fracture occurred. The time to fracture for each instrument was recorded with a stopwatch; in seconds in each group. Fractured instruments were subjected to atomic force microscopy analysis measuring the average roughness and the root mean square values to investigate surface features of endodontic files. Mean values and standard deviation were calculated. Data were analyzed using the Mann-Whitney U test. Results: Time to fracture was marginally higher in PTG instruments than in the TN file systems. PTG files exhibited higher surface roughness when compared with TN files (p<0.05). Conclusion: TN file system had a higher cyclic fatigue resistance than PTG. Cyclic fatigue causing file breakage did affect the surface topography of the files. PTG files showed a higher surface porosity value than the TN files (AU).


Subject(s)
Titanium/chemistry , Microscopy, Atomic Force/instrumentation , Dental Alloys , Dental Instruments , Endodontics , Surface Properties , Statistics, Nonparametric , Dental Pulp Cavity , Hardness Tests , Nickel/chemistry
17.
Rev. bras. med. esporte ; 27(6): 610-615, Nov.-Dec. 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1351784

ABSTRACT

ABSTRACT Introduction: Isokinetics is a tool commonly used in professional soccer. There is ongoing debate among researchers as to the isokinetic reference values a player should have. Objectives: To determine the absolute peak torque (PT) and average work of professional soccer players in relation to their positions on the field, and to establish the reference values for these variables. Methods: Purposeful sampling was used to select 289 professional soccer players. The sample included 32 goalkeepers, 100 defenders, 98 midfielders, and 59 strikers. The participants were measured preseason. The players were asked to perform a 10-minute warm-up on an exercise bike, and then to perform 5 repetitions at low speed, 10 at medium speed, and 25 at high speed, with 30 to 40-s of rest between each set of repetitions. The contraction method was concentric-concentric in a dynamometer Isomed 2000. Results: The average age, weight, and height of the players was 21.9 years, 74.3 kilograms, and 1.8 meters, respectively. The goalkeepers presented higher PT at the 3 measured speeds, and the higher average work at 180°/s and 240°/s in relation to defenders and midfielders. The strikers presented higher average work at 240°/s in relation to midfielders, and higher PT in relation to the defenders and midfielders. Absolute values were shown and reference values were established. Conclusions: The goalkeepers and strikers were the players that showed the greatest differences in their favor in relation to the other positions. The peak torque values and average work were described in relation to the player's position on the field. This study resulted in the creation of a tool for health professionals working with professional soccer players, providing reference values for these players in relation to their position on the field that can be used as benchmarks, by health professionals, to optimize soccer players' performance. Level of evidence II, Prospective comparative study.


RESUMEN Introducción: La evaluación isocinética es una herramienta de uso común en el fútbol profesional. Sigue existiendo debate entre los investigadores sobre los valores isocinéticos de referencia que debe tener un jugador. Objetivos: Determinar el torque máximo (TM) y el trabajo promedio de los futbolistas profesionales en relación a sus posiciones en el campo y establecer los valores de referencia para estas variables. MÉTODOS: Se seleccionó una muestra subjetiva de 289 futbolistas profesionales. Se incluyeron 32 porteros, 100 defensas, 98 centrocampistas y 59 delanteros. Los participantes fueron examinados en la pretemporada. Se solicitó a los participantes que realizaran un calentamiento de 10 minutos en bicicleta estática y luego realizar 5 repeticiones a baja velocidad, 10 a velocidad media y 25 a alta velocidad con 30 a 40 segundos de descanso entre cada serie de repeticiones. El método de contracción fue concéntrico-concéntrico en dinamómetro Isomed 2000. Resultados: La edad, el peso y la altura promedios de los jugadores fue de 21,9 años, 74,3 kilogramos y 1,8 metros, respectivamente. Los porteros presentaron TM más elevado en las 3 velocidades medidas y un mayor trabajo promedio a 180°/s y 240°/s en relación a defensas y centrocampistas. Los delanteros presentaron un mayor trabajo promedio a 240°/s en relación con los centrocampistas y TM más elevado en relación a defensas y centrocampistas. Se mostraron los valores absolutos y se establecieron los valores de referencia. Conclusiones: Los porteros y delanteros fueron los que mostraron mayores diferencias a su favor en relación al resto. Los valores de torque máximo y el trabajo promedio fueron descritos en relación a la posición del jugador en el campo. Los resultados del presente estudio son una herramienta para los profesionales de la salud que trabajan con futbolistas profesionales y proporcionó valores de referencia para estos futbolistas en lo que respecta a su posición que pueden utilizarse como referencia para optimizar el rendimiento. Nivel de evidencia II, Estudio comparativo retrospectivo.


RESUMO Introdução: A isocinética é uma ferramenta comum usada no futebol profissional. Entre os pesquisadores, há um debate contínuo sobre os valores isocinéticos de referência que um jogador deve ter. Objetivos: Determinar o pico de torque (PT) absoluto e o trabalho médio de jogadores de futebol profissional com relação às posições em campo e estabelecer os valores de referência para essas variáveis. MÉTODOS: Foi selecionada uma amostra subjetiva de 289 jogadores de futebol profissional. A amostra incluiu 32 goleiros, 100 zagueiros, 98 meio-campistas e 59 atacantes. Os participantes foram testados na pré-temporada. Os participantes foram solicitados a realizar aquecimento de 10 minutos em bicicleta ergométrica e, a seguir, realizar cinco repetições em baixa velocidade, 10 em velocidade média e 25 em alta velocidade com 30 a 40 segundos de descanso entre cada série de repetições. O método de contração foi concêntrico-concêntrico em um dinamômetro Isomed 2000. Resultados: A média de idade, peso e estatura dos jogadores foi de 21,9 anos, 74,3 quilos e 1,8 metros, respectivamente. Os goleiros apresentaram maior PT nas três velocidades medidas e maior média de trabalho a 180°/s e 240°/s com relação aos zagueiros e meio-campistas. Os atacantes tiveram maior trabalho médio a 240°/s com relação aos meio-campistas e maior PT com relação aos zagueiros e meio-campistas. Os valores absolutos foram mostrados e os valores de referência foram estabelecidos. Conclusões: Os goleiros e atacantes apresentaram as maiores diferenças a seu favor com relação às demais posições. Os valores de pico de torque e trabalho médio foram descritos com relação à posição do jogador em campo. Este estudo resultou na criação de uma ferramenta para profissionais de saúde que atuam com jogadores de futebol profissional e forneceu valores de referência para esses jogadores com relação à posição em campo que podem ser usados como referência para otimizar o desempenho dos jogadores de futebol. Nível de evidência II, Estudo retrospectivo comparativo.

18.
Rev. Univ. Ind. Santander, Salud ; 53(1): e303, Marzo 12, 2021. tab
Article in English | LILACS | ID: biblio-1365445

ABSTRACT

Abstract Background: The study of functional impact of delayed onset muscle soreness has been limited to describe the decline on maximal isometric contraction, but muscular work and time to peak torque has not been examined yet. Purpose: To describe the changes induced by a session of lengthening contractions on muscle performance and delayed onset muscle soreness (DOMS). Methods: A quasi-experimental study was conducted in the Institutional laboratory; Twenty healthy men; mean age 21 SD 0.34 were recruited, all subjects performed 200 lengthening contractions of the quadriceps at 120°/s. Isometric and isokinetic peak torque, muscular work, time to peak torque, DOMS and creatine kinase activity were assessed at baseline, 48 h and 96 h post-exercise. The muscle performance was assessed with an isokinetic dynamometer and DOMS with a visual analog scale (VAS). Results: Relative to baseline, isometric and isokinetic peak torque and muscular work decreased in ~30% at 48 h post-exercise; delayed onset muscle soreness increased ~300%, which remained at 96 h post-exercise. Conclusions: These reflect that the decline in muscular performance is due to the changes in peak torque and muscular work, which has greater implications on muscle function. No changes were detected in time to peak torque. The alterations in muscular performance variables are accompanied by delayed onset muscle soreness which has also a negative impact on force production (29% of the drop on peak torque is explain by soreness intensity).


Resumen Introducción: Los estudios de impacto funcional del dolor muscular de aparición tardía (DMAT) se han limitado a describir la disminución de la contracción isométrica máxima, pero aún no se ha examinado el trabajo muscular y el tiempo del torque máximo. Objetivo: Describir los cambios inducidos por una sesión de ejercicio excéntrico sobre el rendimiento muscular y DMAT. Método: se realizó un estudio cuasi-experimental, los participantes fueron veinte hombres sanos; edad media 21 DE 0,34, todos los sujetos realizaron 200 contracciones excéntricas del cuádriceps a 120°/s. Se evaluó el torque pico isométrico e isocinético, el trabajo muscular, el tiempo hasta el torque máximo, DMAT y la actividad de la creatina quinasa al inicio, 48 h y 96 h después del ejercicio, el rendimiento muscular se evaluó con un dinamómetro isocinético y DOMS con una escala análoga visual (EAV). Resultados: en relación con la línea de base, el torque pico isométrico e isocinético y el trabajo muscular disminuyeron en ~ 30 % a las 48 h post-ejercicio; El dolor muscular de aparición tardía aumentó ~300 %, que permaneció 96 h después del ejercicio. Conclusiones: los resultados reflejan que la disminución del rendimiento muscular se debe a los cambios en el torque pico y trabajo muscular, lo que tiene mayores implicaciones en la función muscular. No se detectaron cambios en el tiempo hasta el torque máximo. Las alteraciones en las variables de rendimiento muscular se acompañan de DMAT que también tiene un impacto negativo en la producción de fuerza (el 29 % de la caída en el torque máximo se explica por la intensidad del dolor).


Subject(s)
Humans , Male , Adult , Myalgia , Physical Functional Performance , Musculoskeletal System , Torque , Creatine Kinase , Muscle Strength Dynamometer , Isometric Contraction , Isotonic Contraction
19.
Rev. bras. ciênc. esporte ; 43: e012820, 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1288261

ABSTRACT

ABSTRACT We aimed to assess upper and lower limbs explosive strength, and its correlation with biceps brachii (BB) and vastus lateralis (VL) architecture. Absolute and maximum torque normalized rate of torque development (RTD) were measured from isometric elbow flexion (EF) and knee extension (KE). BB and VL architectures were assessed by ultrasound. Absolute RTD of KE was higher (129-272%), although normalized RTD was higher in EF (80-21%). The absolute RTD was correlated to muscle thickness only in the BB (r=.39-46). No relationship was found between muscle architecture and normalized RTD. In conclusion, the higher RTD from KE seems to be due to their greater strength. Only the muscle architecture could not explain the differences found in the RTD.


RESUMO Nosso objetivo foi avaliar a força explosiva de membros superiores e inferiores e a sua correlação com a arquitetura do bíceps braquial (BB) e vasto lateral (VL). A taxa de desenvolvimento de torque (TDT) absoluta e normalizada pela força máxima foi medida na flexão de cotovelo (FC) e extensão de joelho (EJ). A arquitetura do BB e do VL foi avaliada por ultrassonografia. A TDT absoluta de EJ foi maior (129-272%), mas a TDT normalizada foi maior na FC (80-21%). A TDT absoluta foi correlacionada com a espessura do BB (r=.39-46). A TDT normalizada não foi correlacionada à arquitetura muscular. Concluindo, a TDT superior da EJ parece causada pela maior força máxima. Apenas a arquitetura muscular não parece explicar a diferença na TDT.


RESUMEN Nuestro objetivo era evaluar la fuerza explosiva de los miembros superiores y inferiores y su correlación con la arquitectura del bíceps braquial (BB) y vasto lateral (VL). Se medio la tasa de desarrollo de torque (TDT) absoluta y normalizada por la fuerza máxima in la flexión de codo (FC) e extensión de rodilla (ER). La arquitectura del BB y VL fue evaluada por ultrasonido. La TDT absoluta de ER fue mayor (129-272%), pero la TDT normalizada fue mayor en la FC (80-21%). La TDT absoluta se correlacionó con el grosor del BB (r=.39-46). La TDT normalizada no se correlacionó con la arquitectura. En conclusión, la TDT superior del ER parece estar causado por la mayor fuerza máxima. La arquitectura muscular sola no parece explicar la diferencia en la TDT.

20.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1145466

ABSTRACT

Objectives: With regard to the prevalence of abutment screw loosening (SL) and bone height reduction, particularly in the posterior regions of the jaws, as well as the contradictory issue of applying short implants instead of surgeries, along with all preparations associated with longer implants, the present study aimed to compare the amount of torque loss in short implants with increased vertical cantilever abutments and standard ones. Material and Methods: In this experimental study, a total number of 20 implants (MegaGen Implant Co., Ltd, South Korea) with 4.5 mm diameter including 10 short implants (7 mm) and 10 standard ones (10 mm) were utilized. Using a surveyor, fixtures were perpendicularly mounted in 13×34 mm resin for short implants and 19×34 mm resin for standard ones. The abutments of the same height but different cuff heights (2.5 mm for the standard implants and 5.5 mm for the short ones) were then tightened with 30 N.cm, via a digital torque meter. To compensate the settling effect, the abutment screw was re-tightened with 30 N.cm after 10 min. Upon applying 500,000 cycles at 75 N.cm and 1 Hz along the longitudinal axis on each sample, blind reverse torque value (RTV) was measured with a digital torque meter. The data were finally analyzed using Student's t-test. Results:Both groups experienced torque loss, but there was no statistically significant difference between the case and control groups in terms of abutment SL (p = 0451). Conclusion: Short implants seem to be a good mechanical alternative in emergencies with respect to torque loss and abutment SL. (AU)


Objetivos: Considerando a prevalência de afrouxamento de parafuso dos pilares, redução da altura óssea especialmente nas regiões posteriores, a questão contraditória da aplicação de implantes curtos em vez de cirurgias e todos os preparos associados a implantes mais longos, este estudo buscou comparar implantes curtos com pilares cantilever verticais aumentados e implantes padrão na quantidade de perda de torque. Material e métodos: Neste estudo experimental, foram utilizados 20 implantes (Megagen, Coreia do Sul) com diâmetro de 4,5 mm, incluindo 10 implantes curtos (7 mm) e 10 implantes padrão (10 mm). A fixação foi realizada perpendicularmente em uma resina 13 × 34 mm para implantes curtos e uma resina 19 × 34 mm para implantes padrão, usando um topógrafo. Os pilares da mesma altura, mas com diferentes comprimentos de manguito (2,5 mm para os implantes padrão e 5,5 mm para os implantes curtos) foram apertados com 30 N, utilizando um torquímetro digital. Para compensar o efeito de sedimentação, o parafuso do pilar foi reapertado com 30 N após 10 min. Depois de aplicar 500.000 ciclos a 75 N e 1 Hz ao longo do eixo longitudinal em cada amostra, o valor de torque reverso cego foi medido com um medidor de torque digital. Os dados foram analisados pelo teste t de Student. Resultados: Todos os grupos tiveram perda de torque, mas não houve diferença estatisticamente significativa entre os grupos caso e controle em termos de afrouxamento do parafuso do pilar (p = 0451). Conclusão: Os implantes curtos parecem ser uma boa alternativa mecânica em emergências em termos de perda de torque e afrouxamento do parafuso do pilar. (AU)


Subject(s)
Bone Screws , Torque , Dental Implantation
SELECTION OF CITATIONS
SEARCH DETAIL